3P60K-AD3-100A-EU01 | 3P60K-AD3-80A-EU02 | |||||
Power Input |
Input Rating | 400V 3ph 125A max | 400V 3ph 125A max | |||
Number of Phase/Wire | 3ph/L1.L2.L3, PE | |||||
Power factor | >0.98 | |||||
Current THD | <5% | |||||
Efficiency | >95% | |||||
Output Power |
Output Power | DC:60KW AC:43KW |
DC:60KW AC:43KW |
|||
Remark: Only one gun is available in a charging session | ||||||
Output rating | 200V-750V Dc | 200V-1000V DC | ||||
Protection | Protection | Over current, under voltage, over voltage, Residual current, Surge protection, Short Circuit, Over temperature, Ground Fault | ||||
User interface & control | Display | 7” touch screen | ||||
Support Language | English (Other language available upon request) | |||||
Charge Option | Charge option to be provided upon request: Charge by duration, Charge by energy, charge by fee | |||||
Charging Interface | CSS2 / CHAdeMO / Control Pilot | |||||
User authentication | PayPal and NFC card | |||||
Communication | Network Interface | Ethernet (standard); Wi-Fi, 4G (Optional) | ||||
Open charge point protocol | OCPP1.6 / OCPP2.0 | |||||
Environmental | Operating temperature | Minus 20deg C to 55deg C (Derating when over 55deg C) | ||||
Storage temperature | -40deg C to +70deg C | |||||
Humidity | <95% relative humidity, non-condensing | |||||
Altitude | Up to 2000m (6000 feet) | |||||
Mechanical | Ingress protection | IP54 | ||||
Enclosure protection against External Mechanical impacts | IK10 according to IEC 62262 | |||||
Cooling | Forced Air | |||||
Charging cable length | ||||||
Dimension | 5m | |||||
Weight | 500*600*1500 | 500*600*1500 | ||||
Regulation | Certificate/Compliance | CE / EN / 61851-1/-23 |